Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
Permit Number - T02CM03748
Inspection Description - PLUMBING - ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/23/2002 | PLUMBING - ABOVE CEILING | Approved | IVRS - Inspection 0000* | |
09/09/2002 | PLUMBING - ABOVE CEILING | Denied | IVRS - Inspection 0999*1.) ABS DWV UNDERGROUND OK WATER TEST OK TIE-IN TO EXISTING OK 2.) ABS DWV ABOVE GRADE OK WATER TEST OK OK TO TIE-IN VENT TO EXISTING OK TO COVER UNDERGROUND NOTE JUST A REMINDER TRAPS TO BE THE SAME SIZE AS THE TRAP ARM TO WHICH THEY ARE CONNECTED. ANY CHANGE WILL REQUIRE TEST AND RE-INSPECTION. 3.) PLUMBER PLEASE READ PLUMBING SPEC'S ALL HOT WATER PIPING TO BE INSULATED W/1/2" THICK FIBER GLASS INSULATION. NO PROVISION MADE IN HANGERS AND SUPPORTS TO ALLOW FOR INSULATION. GO AHEAD AND INSULATE, AND RECALL FOR INSPECTION. |