Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM03715
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
10/09/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) BLOCK AND NAIL ROOF OSB THAT COVERS ONLY ONE TRUSS BAY 2) BLOCK AND NAIL OFF RIDGE PER DETAIL 3) ONE ROW MISSED NAILING ON NORTH ROOF PLANE 4) NORTHWEST SITE BUILT TRUSS NEED IT'S VERTICLES CLIPPED DOWN TO TOP PLATE AND UP TO TOP CORD 5) PATIO-FINISH COLUMNS, STRAP HEADERS SHIM 3 POINT BEARING TRUSSES 6) NAIL OFF TRUSS BRACKETS EAST OF FRONT ENTRY 7) H2.5 TRUSSES OVER FRONT ENTRY 8) STRAP FRONT ENTRY GABLE TRUSS DOWN TO CLIPPED KINGS |