Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 09/30/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 09/26/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) PEX PLUMBING NOT PROPERLY INSTALLED TO COUPLINGS ELBOWS AND FITTINGS. PROVIDE IAPMO INSTALLATION STANDARDS FOR PEX AND COMPLY. TUBING MUST BE WITHIN 1/16" OF FITTING STOP 2) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE |
| 09/25/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) NO DWV WATER TEST PER UPC 712.2 2) NO PRESSURE ON POTABLE WATER 3) PEX CONNECTIONS NOT PROPERLY MADE. TUBING MUST BE WITHIN 1/16" OF STOP ON CONNECTORS 4) COULD NOT LOCATE PLAN |
| 09/24/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0950* |