Date Description Inspector Results Comments
12/27/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/20/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) ALL BUT CARPORT-OK
09/19/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) MISSED 1ST ROW TJ ROOF NAILING SOUTH SIDE 2) ALL SHEAR WALLS TO BE BOLTED MINIMUM A BOLTS SEE PLAN 3) CARPORT NOT BUILT YET 4) NO PAPER WORK LEFT FROM LAST INSPECTION 5) CHECK SPACING ON ROOF TJI VERY SONGEY WHEN WALKED ON 6) SET BACK NOTE ON PLANS AND PERMIT 10' EAST SIDE AND 9' AT REAR YOU DON'T HAVE EITHER, LPI 32 24' ON CENTER 25'-6"
09/18/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) LEDGER CLIPS OK TO COVER 2) ONE TJI JOIST MISSING