Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/24/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/23/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) REPLACE DIAGONAL BRACING FOR GABLE END TRUSSES REPAIR CROSS BRACING ON NORTH END 2) REROUTE PEX PIPING, TO REFRIGERATOR, AWAY FROM CAN LIGHT FIXTURE AT LEAST 12" AWAY 3) NEED ADDITIONAL PIPE CLAMPS ON LONG RUNS OF GAS PIPING 4) COMPLETE A/C REFRIGERATOR LINE AND CONDENSATE PIPING 5) REROUTE 12" FLEX DUCT ON EAST SIDE, NORTH END OF UNIT AROUND CROSS BRACING " DO NOT CUT CROSS BRACING" |