Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/07/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/03/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ISOLATE GROUNDS AND NEUTRALS AT SUB-PANEL 2) GROUND SUB-PANEL FROM MAIN 3) CAULK AT PANEL 4) INSTALL CLEANOUT AT BATH EXTERIOR 5) PAINT VENT AT ROOF 6) INSTALL BACKFLOW AT EXTERIOR TAP 7) SECURE A/C FLEX WITHIN 12" OF SUB-PANEL AND SECURE A/C LINES TO BIRD BOARD 8) SEAL A/C LINES AT INSULATION TEARS 9) INSTALL CONDENSATE PER CODE 10) GFCI COUNTER OUTLETS 11) INSTALL 3' X 3' LANDING AT WALK-THRU 12) CORRECT ALL ITEMS NOTED AND RECALL |