Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/21/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/17/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE APPROVED PLANS 2) UNION CANNOT BE INTO WALL MUST BE ACCESSIBLE AND PROVIDE A NEW GAS PRESSURE TEST 3) HOUSE LOCKED |
| 01/14/2003 |
BUILDING - FINAL |
|
Partial Approval |
1) FROM LAST INSPECTION SOLDER 90 DEGREES AT HVAC 2) EXTEND GAS LINE OUT OF WALL, ATTACH GAS BOND |
| 01/13/2003 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) SOLDER 90 DEGREE ON T&P AND CONDENSATE 2) HVAC ELECTRIC NOT COMPLETE, UNITS NOT CONNECTED 3) GAS BOND CLAMP NOT INSTALLED |