Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM03609
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/22/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) #1 BRACED WALL PANELS MUST HAVE AB WITHIN 12" OF PANEL EDGES MUST BE SPLICED ON SAME FRAME MEMBER OR TIE AT 16" ON CENTER 2) PAHD42 MISSED INSTALL LTT2D WITH 1/2 A3. AT PORCH 3) POST DOUBLE GIRDER POSTS ALL WAY TO GROUND 4) CLIP HIPS AT CORNERS 5) NAIL EXTERIOR BOTTOM PLATES AT 2-16D 12" ON CENTER |