Permit: T02CM03609

Parcel: 123112410

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM03609

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/13/2002 FRAMING Approved IVRS - Inspection 0000*
11/22/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) #1 BRACED WALL PANELS MUST HAVE AB WITHIN 12" OF PANEL EDGES MUST BE SPLICED ON SAME FRAME MEMBER OR TIE AT 16" ON CENTER 2) PAHD42 MISSED INSTALL LTT2D WITH 1/2 A3. AT PORCH 3) POST DOUBLE GIRDER POSTS ALL WAY TO GROUND 4) CLIP HIPS AT CORNERS 5) NAIL EXTERIOR BOTTOM PLATES AT 2-16D 12" ON CENTER