Inspection Status: Approved
Inspection History: BUILDING ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/06/2002 |
BUILDING ABOVE CEILING |
|
Approved |
IVRS - Inspection 0000* |
| 09/05/2002 |
BUILDING ABOVE CEILING |
|
Denied |
IVRS - Inspection 0999*1.) SEE ATTACHED ASTM C636 STANDARD 2.3.3. NO KINKS OR BENDS IN WIRES TO PROVIDE LEVELING 2.3.4. FIGURE 1-3 TURES IN 3" 2.1.3 SPACE HANGERS 4 FT O.C. MAXIMUM. |
| 09/04/2002 |
BUILDING ABOVE CEILING |
|
Denied |
IVRS - Inspection 0999*1.) INSTALL CEILING GRID PER ASTEM & CISCA STANDARDS. A.) WIRES 4' ON CENTER MAXIMUM BOTH DIRECTIONS. B.) WIRES TO BE TO TWISTED 3 FALL TURNS WITHIN 3" |