Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM03564
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
09/10/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) OVER FRAME REQUIRES 2 X 8 VALLEY PLATE SEE FRAMING PLAN (S-3) AND DETAIL (14-SD4) 2) SOUTH WALL REQUIRES MORE BRACING REQUIRED 25' MAXIMUM SPACING 3) ADD X BRACE ON TRUSSES AT APPROXIMATE MIDDLE ROOF SHEATHING NAILING OK 4) DOUBLE STUD REQUIRED AT BEARING OF GIDER TRUSS TYP |