Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/10/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/09/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NAIL OFF ALL HOLES IN FHA STRAPS 2) SEAL DUCT CHASE DRAFT STOP AT LOFT ENTRY |
| 10/07/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT GAS MAIN RISER AND 4" PLUMBING IN GARAGE REAR WALL 2) TAPE VENT FAN DUCTS AT VENT CONNECTION 3) PLUMBING LEAK AT MASTER TOILET AND FRIDGE BOX 4) SHIM 2ND FLOOR FLOOR TRUSSES AT BEARING NEXT TO STAIRS 5) SHIM STAIR STRINGER BEARING AT TOP 6) DETAIL OF SUPPORT AT STAIRS THAT CARRIER 2ND FLOOR GLU LAM 7) PROVIDE CLEARANCE TO COMBUSTIBLES AT FIREPLACE FLUE 8) SEAL CUT FIRE BLOCK AT KITCHEN GAS 9) FHA STRAP BOTTOM PLATE AT KITCHEN UNDER GROUND ELECTRIC AND KITCHEN SHEARWALL TOP PLATES AT PLUMBING10) BLOCK LINING DUCT BOOT 11) GET DETAIL FOR BOTTOM CORD CONNECTION OF LIVING ROOM ROOF TRUSSES 12) STOPPED INSPECTION AFTER 1ST FLOOR |