Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T02CM03551
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/26/2003 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
06/20/2003 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) INSTALL THREADED CAPS ON SEWER CLEANOUTS AND TRIM TO GRADE 2) INSTALL 2160 ADDRESS ON HOUSE MINIMUM 3" HIGH NUMBERS 3) SEAL FURNACE TO PLATFORM 4) SEAL GARAGE CEILING PENETRATIONS 5) INSTALL WATER HEATER GAS LINE 6) CAP UNUSED GAS LINE 7) BARE BULB LIGHT FIXTURE NOT ALLOWED IN CLOTHES CLOSETS 8) KITCHEN OUTLETS MUST BE GFCI PROTECTED AND WITHIN 12" OF TOP 9) PROVIDE ACCESS TO JACCUZI OPENING 21 1/4 X 25 1/4 WITH OPENING 3.76 SF 10) MASTER BEDROOM DOES NOT HAVE EGRESS, WINDOW TO SMALL |