Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/12/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 12/02/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0925*/ 1) COULD NOT FIND PLANS |
| 11/24/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) H.25 REQUIRED FROM LEDGER TO STUD AT FRONT PORCH LEDGER SEE DETAIL 16/S4 |
| 11/14/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) VERIFY POSITIVE CONNECTION PORCH BEAM TO POSTS 2) NEED POSITIVE CONNECTION PORCH LEDGER TO STUDS 3) STAPLES AND OR NAILS EITHER DRIVEN TO DEEP OR NOT DEEP ENOUGH (RENAIL) 4) STOPPED INSPECTION 5) CORRECT ALL AND RECALL |