Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM03550
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/07/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/06/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) TOO MUCH GAP METAL FIRESTOP SPACER AROUND FIREPLACE FLUE 2) NOTCHED STUD DIVERTER VALVE NEEDS RE-INFORCING 3) UNABLE TO LOCATE HANGER USED IN GARAGE ON PLANS 4) ALSO MAY NEED TO USE 10D NAILS IN HANGERS | |
10/31/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) MOVE PEX AWAY FROM 12" WATER HEATER FLUE 2) LEAVE TRUSS DRAWINGS ON SITE 2 X 6 HANGER USE CORRECT NAILS. HANGER NOT SPECIFIED ON PLAN, CHECK LEAD FROM TRUSS DRAWINGS 3) FIRESTOP AT FIREPLACE NEED TWO 1/2" LAYERS OF PLY AND METAL FIRESTOP AROUND FLUE 4) MOVE HEARTH SAFETY STRIP 2" UNDER FIREPLACE SEE INSTRUCTIONS 5) GAS RANGE STRIKER OUTLET 6) SUPPORT STUD AT DIVERTER VALVE NOTCHED 7) MOVE PEX AT REAR BATH CAN LIGHT 8) CHECK TRUSS DRAWINGS FOR LATERAL BRACES 9) BANG PALTE AT ELECTRIC TOP PLATE AT SERVICE | |
10/25/2002 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) INSTALL FIRESTOP FIREPLACE 2) MAINTAIN MINIMUM 2" CLEARANCE FIREPLACE FLUE TO COMBUSTIBLES 3) WATER TEST DWV SYSTEM AND WATER PIPING SYSTEM 4) INSTALL FLUE PIPE WATER HEATER 5) LADDER ACCESS OPENING NOT ALLOWED GARAGE FIREWALL CEILING 6) INSTALL HANGERS FRONT PORCH AT ALL BEARING POINTS 7) SECURE ELECTRIC WIRES AWAY FROM FLUE PIPE 8) HAVE INTERMEDIATE PLUMBING PUT ON PERMIT | |
10/02/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |