Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM03540

Parcel: 141147450

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/07/2002 FRAMING Approved IVRS - Inspection 0000*/ 1) ALL CORRECTIONS REQUESTED FROM PRIOR INSPECTIONS ARE COMPLETED
11/06/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) SCREW FIREPLACE TO FRAME 2) BANG PLATE PEX AT FRIDGE TOP PLATES AND AT 2 VENT PIPES AT FRONT OF HOUSE NEXT TO GARAGE (STUDIO) 3) CUT RADIANT BARRIER UP FROM TOP PLATES WHERE NEEDED FOR INSULATION 4) SHIM HEADERS WHERE NEEDED 5) FIREBLOCK ENTRY COLUMN AND MASTER BATH COLUMNS 6) TIGHTEN GROUND SCREW IN PANCAKE IN STUDIO 7) SUPPORT VENT 90 DEGREE IN MASTER BATH 8) GROUND PANCAKES OUTSIDE MASTER CLOSET
11/04/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) BANG PLATE PEX IN SOUTH GARAGE WALL 2) CUT RADIANT BARRIER AWAY FROM FLUES AND UP FROM TOP PLATES FOR INSULATION (WHERE NEEDED) 3) REMOVE STAPLES FROM BEHIND HOME RUNS AT ELECTRIC PANEL 4) NO HILTI'S OR RED HEADS IN REAR GARAGE WALL 5) GROUT TUBS 6) REPAIR FIRE STOP ABOVE FIREPLACE 7) RE-FRAME FRIEPLACE OPENING 8) PLATE WIRES ABOVE 4 GANG ON SOUTH FIRE PLACE WALL 9) STOPPED INSPECTION 10) NORTH ROOMS AND FIREPLACE ROOM INSPECTION COMPLETED 11) DWV AND WATER TEST OK 11/4
10/29/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*