Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/23/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ 1) OK TO DRYWALL |
| 08/20/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SMOKE DETECTORS MUST BE INNER CONNECTED TO ALL TRIP WHEN ONE GOES OFF. REQUIRES 14-3 G BETWEEN UNITS 2) SMOKE DETECTOR NOT ALLOWED WITHIN 36" OF AIR REGISTER (HALL) 3) PEX PLUMBING NOT ALLOWED WITHIN 12" OF RECESSED LIGHT 4) DRYER VENT MUST EXHAUST OUTSIDE |