Permit: T02CM03473

Parcel: 136011390


Addresses:

8160 E SNAKEROOT DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/09/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) REINSPECTION
09/03/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP GARAGE HEADER 2) STRAP NON-CABIN TIED TO PLATES-REAR CORNERS AND FRONT DOOR AREA 3) INSTALL STRUCTURAL RAFTERS INSIDE ROUGH SAWN RAFTERS ON PATIO