Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM03449

Parcel: 141013900

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM03449

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/15/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/09/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SHEARWALLS NOT PER PLAN SHEET A1.1 2) A REINSPECTION FEE HAS BEEN ATTACHED TO THIS PERMIT
10/04/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NO PLAN/PERMIT ON SITE 8:20 AM
10/03/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) UNABLE TO INSPECT WITHOUT PLAN
10/01/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) HTT16 MISSING BOLTS 2) SW3 ANCHOR BOLTS 24" SPACING