Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: ELECTRIC - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/04/2002 |
ELECTRIC - ABOVE CEILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/26/2002 |
ELECTRIC - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection 0000*1.BE ADVISED 1.) ANY 2 X 4 LAY IN FIXTURES MOVED OR ADDED MUST BE FILLED WITH SEISMIC WIRES (2 WIRES AT OPPOSITE CORNERS) AND MUST BE SCREWED TO THE GRID. IF FIXTURES HAVE EARTHQUAKE CLIPS THESE MAY BE TURNED OUT TO ENGAGE THE T GRID IN LEIU OF SCREWS. 2.) COMPLETE ALL J BOX AND COVER 3.) REMOVE ANY ABANDONED WIRING AND FLEX CONDUIT WHIPS. |