Permit: T02CM03445

Parcel: 13411361B


Addresses:

1114 S SARNOFF DR

Inspection Status: Approved

Inspection History: ELECTRIC - ABOVE CEILING

Date Description Inspector Results Comments
12/04/2002 ELECTRIC - ABOVE CEILING Approved IVRS - Inspection 0000*
11/26/2002 ELECTRIC - ABOVE CEILING Partial Approval IVRS - Inspection 0000*1.BE ADVISED 1.) ANY 2 X 4 LAY IN FIXTURES MOVED OR ADDED MUST BE FILLED WITH SEISMIC WIRES (2 WIRES AT OPPOSITE CORNERS) AND MUST BE SCREWED TO THE GRID. IF FIXTURES HAVE EARTHQUAKE CLIPS THESE MAY BE TURNED OUT TO ENGAGE THE T GRID IN LEIU OF SCREWS. 2.) COMPLETE ALL J BOX AND COVER 3.) REMOVE ANY ABANDONED WIRING AND FLEX CONDUIT WHIPS.