Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM03443

Parcel: 125071330


Addresses:

2703 E 6TH ST #02


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T02CM03443

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/27/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
08/23/2002 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*/ 1) NEED 1/4" PITCH PER FT SOIL TRUNK AND SEWER 2) INSTALL TUB ON IT'S OWN DRAIN LINE, SUPPLY CLEANOUT AT EXTERIOR WALL 3) FLAT VENT TOILET COME OFF 3" TRUNK WITH AT 45" AND 1/8" BEND, OR COMBO FITTING, TO WALL 12" CENTER CLOSET BEND FLANGE TO FINISH WALL, WITH 2" PIPE 4) REVENT FOR LAV HT 42" ABOVE FIRST FLOOR