Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T02CM03443
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2002 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* | |
| 08/23/2002 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NEED 1/4" PITCH PER FT SOIL TRUNK AND SEWER 2) INSTALL TUB ON IT'S OWN DRAIN LINE, SUPPLY CLEANOUT AT EXTERIOR WALL 3) FLAT VENT TOILET COME OFF 3" TRUNK WITH AT 45" AND 1/8" BEND, OR COMBO FITTING, TO WALL 12" CENTER CLOSET BEND FLANGE TO FINISH WALL, WITH 2" PIPE 4) REVENT FOR LAV HT 42" ABOVE FIRST FLOOR |