Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM03431
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/16/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/13/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE ADDITIONAL STUD AND FHA STRAP AT 1ST FLOOR REFER LINES THROUGH TOP PLATE 2) NAIL PROTECT CONDENSATE LINE 1ST FLOOR 3) CLEAN TRASH AWAY FROM WATER HEATER VENT 4) REPLACE BROKEN STUD 2ND FLOOR EAST SIDE | |
09/12/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) TIGHTEN RED HEAD AT FRONT DOOR 2) SECURE GAS PIPE AT DRYER 3) BLOCK DUCT BOOTS IN DOWN BATH AND LAUNDRY 4) MOVE PEX 12" FROM KITCHEN CAN LIGHT 5) REPAIR DUCT BOOT BLOCK IN DINING 6) REPAIR 1ST FLOOR TOP PLATES AT HVAC LINES 7) CORRECT/REPAIR DUCTS AT DINING METAL GUSSETS 8) H2.5 WEST DINING TRUSS 9) DEN DOOR HEADER NEEDS DOUBLE TRIMMERS 10) STOPPED INSPECTION AFTER 1ST FLOOR |