Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/06/2003 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE OK. 2) OK TO COVER ALL AREAS. |
| 08/03/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) 1002.3 TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREE 2) 1002.2 TRAP ARM DISTANCE 3) 1002.4 POINT OF VENT MAY NOT BE BELOW TRAP WEIR 4) TABLE 3-1 HORIZONTAL SUPPORT OF ABS 5) 301.1.2 LISTED MATERIALS IE STRAPS AND SUPPORTS |
| 07/30/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) SEE NOTE #3 FROM 7/22/03 |
| 07/22/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) PLUMBER MUST MAKE ALL CORRECTIONS FROM 7/14/03, PLUS T&P RELIEF DRAIN NOT APPROVED MATERIAL TYPE. 2) TRAP ARM CLEAN OUT TEES NOT APPROVED. 3) HAVE PLUMBER ON SITE AT TIME OF NEXT INSPECTION. 4) NOT INSTALLED PER PLAN. APPROVED PLAN STILL SHOWS MANA BLOCK. |
| 07/14/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) NOT INSTALLED PER PLAN. WATER DISTRIBUTION TO BE MANA BLOCK-BESIDES, ONLY TWO FIXTURES ALLOWED ON 1/2" 2) HERE IS A PARTIAL CORRECTION LIST-CHECK ALL WORK. TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREE WITHOUT ADDITIONAL CLEANOUT. POINT OF VENT BELOW WEIR OF TRAP. TRAP ARM EXCEEDS ALLOWABLE LENGTH. TABLE 3.1 HANGERS AND SUPPORTS |