Permit: T02CM03408

Parcel: 128070910


Addresses:

5951 E ELI ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/07/2003 FRAMING Approved IVRS - Inspection 0000*
02/04/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) FINISH FRAME AT SHOWER 2) BANG PLATE ELECTRIC AND PLUMBING WHERE NEEDED 3) GROUND ALL METAL BOXES-GREEN SCREW 4) WRAP TUB DRAIN PRIOR TO POUR