Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T02CM03405
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2002 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000* | |
| 12/20/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* INSPECTOR WILL LOOK IN BOXES AFTER ROCK INSTALLED IF NOT IN COMPLIANCE WITH NOTE #2 ROCK. |
|
| 12/17/2002 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* | |
| 12/13/2002 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0245*NOTES 1.) ROMEX IN CIELING AREAS NOT SUPPORTED PER NEC. 2.) SEE ITEM #1 EAST INSPECTION WRITE UP. 3.) NEED TO VERIFY NAME & PH# OF LICENSED ELECTRICAL CONTR. DOING WORK. 4.) REVISE PLANS TO INDICATE TYPE OF SERVICE EQUIP. USE. PLANS SHOW A SINGLE METER ALL IN ONE, 125A. DUAL PACK 200AMP INSTALLED. |
|
| 12/09/2002 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) OK ITEM #2 - 1999 NEC ARTICLE 370-17-C ROMEX SHEATH SHALL EXTEND INTO BOX LIMIT 1/4" PLUS SOME OK NOT ALOT. #3 OK #4 ROMEX CONNECTORS TO BE USED ONLY FOR THE LISTEN AMOUNT OF CABLES EACH CAN HOLD THERE IS NO APPROVAL FOR A CONNECTOR TO ALLOW AS MANY LABELS AS POSSIBLE 110-3 B USE EQUIPMENT AS LISTED. NOT IN BUT OK TO COVER FIRE WALL SUBJECT TO OTHER INSPECTIONS. |
|
| 12/04/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* 1.) FINISH MAKE UP OF BOXES EVEN WHERE YOU HAVE ONE CABLE. 2.) PLEASE TO MUCH COVERING OF ROMEX INTO BOXES, LIMIT TO APPROX. 1/4" 3.) USE ROMEX CONNECTOR IN LIEU OF K.O. BUSHING. 4.) K.O. BUSHING AT TOP OF PANEL USE ROMEX CONNECTORS. 5.) FIRE WALL PENETRATIONS SUBJECT TO BUILDING INSPECTOR. |