Permit: T02CM03388

Parcel: 122152410

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
04/16/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
04/03/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) EXTERIOR OUTLET MUST BE GFCI PROTECTED 2) ROMEX BELOW 6'-8" MUST BE PROTECTED 3) 2 OUTLETS ON WEST WALL HAVE HOT-NEUTRAL REVERSE CONDITION 4) INSTALL SMOKE DETECTORS IN SLEEPING ROOMS AND ADJOINING HALLWAYS ON CEILING OR WITHIN 18" OF CEILING