Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2002 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection 0000*1.) INSTALL AB'S FOR LEDGER BUTT JOINTS OK TO GROUT I WILL LOOK FOR AB'S @ FRAMING INSPECTION. | |
| 11/19/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*20' | |
| 11/15/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*DETAILS ON SSES CALL FOR SIMPSON PATM STRAPS GROUTED SOLID. SIMPSONS INSTALLATION GUIDELINES CALL FOR OR 2' THIS BAR IS NOT INDICATED ON PLAN. PLEASE PROVIDE RFI ABOUT THIS. | |
| 11/12/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1.) PARTIAL 12' 2.) 6' FOOT THICK MASONRY LINTEL 80% COMPLETE OK TO POUR IF SPECIAL INSPECTOR NOTES IT IS COMPLETE & IN COMPLIANCE. |
|
| 11/07/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1.) MAINTAIN #6 BARS @ EACH FACE WITH 1" MIN SEPERATION. 2.) KEEP OTHER VERTS CENTERED IN GROUT CELLS 3.) DO NOT GROUT OR PLACE ANY CONCRETE WITHOUT APPROVAL OF THE BUILDING OFFICIAL. 4.) OK TO GROUT TO 8'. |
|
| 11/04/2002 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection 0000*1ST LIFT. |