Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 09/18/2002 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 09/09/2002 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) TUB IS UNVENTED 2) USE (1 1/2" PIPE FOR DRAIN) SAME AS PEE TRAP= 1 1/2 3) ALL SAN-TEES TO BE REPLACED WITH COMBO'S OR WYE FITTING AND 1/8 BENDS 4) SHADE ALL HORIZONTAL DRAIN LINES, MAINTAIN 1/4" PER FT. OF SLOPE 5) TOILET VENTED INCORRECTLY 6) ANY FIXTURE MORE THAT 5' FROM HORIZONTAL MAIN TRUNK LINE REQUIRES A CLEAN OUT |