Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM03306
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/06/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/05/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT MASTER PLUMBING VENT-NOT BANG PLATES 2) WAITING FOR CLEARANCE FOR DRYER VENT LENGTH | |
09/04/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA TOP PLATES AT GAS MAIN AND WATER MAINS AND AT MASTER VENT STACK 2) NEED 2-2 X 4 STUDS UNDER GIRDER TRUSS FOR 3RD CAR OPTION-EAST END 3) PROVIDE 1" OSB CLEARANCE TO HOT WATER FLUE 4) DRYER VENT IS TO LONG 5) CORRECT OVER NOTCHED STUD IN KITCHEN EXTERIOR WALL 6) NORTH TOP PLATE IN MASTER CLOSET-NOT 3 POINT BEARING | |
09/03/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NOTE: ON 8/21/02 YOU WERE NOTIFIED THAT THIS HOUSE IS MISSING THE REQUIRED #5 SHEARWALL IN THE GARAGE. THIS IS REQUIRED WHEN 3 CAR GARAGE AND DEN OPTION IS USED. THE PLAN ON SITE TODAY DOES NOT INCLUDE THAT OPTION COMBINATION. THE PLAN ON SITE MUST REFLECT ALL OPTIONS THAT ARE ACTUALY BUILT ON THAT PROPERTY. NO FURTHER INSPECTION WILL BE DONE WITHOUT THE CORRECT PLAN |