Permit: T02CM03279

Parcel: 141302320

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM03279

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/12/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/09/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROVIDE STRAPS AT ENTRY DOUBLE BEAMS 2) PROVIDE BLOCKING AT TRUSS BRACE LOCATIONS PER SD 413 3) PROVIDE CS20 STRAP AT BAY WINDOW BEAM TO TOP PLATE CONNECTION