Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM03268
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
| 08/05/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0925*/ 1) UNTREATED 6 X 6 POST MUST HAVE 1" CLEARANCE TO CONCRETE 2) NO CITY OF TUCSON APPROVED PLANS ON SITE 3) STUDS NOT CLIPPED |