Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/13/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) OK FOR DRYWALL. |
| 08/08/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*1.)REVENT FOR LAVATORY FOR MENS RM MUST BE MIN 6" ABOVE FLOOD RIM LEVEL WHEN VENT GOES FROM VECTICAL TO HORIZONTAL. 2.) RETEST SYSTEM 3.) MUST REMOVE C.O. TEE IN PLBG. WALL AND USE WYE AND PERM. CAP. |
| 08/07/2002 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*NOT READY FOR INSPECTION. |