Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
The login landing page when selecting 'View' is still occurring and is still pending further investigation.
Inspection Status: Denied
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/16/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 08/16/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 08/13/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PARTIAL ON PLUMBING INTERMEDIATE INSIDE STRUCTURE ONLY 2) WINDOW SIZE NORTH SIDE OWNERS UNDECIDED |
| 08/12/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) POST CLIPS NOT NAILED POST CAPS NOT INSTALLED 2) NAIL CORNER BAKED PANELS AT 6" ON CENTER AT ALL EDGES AND TOP AND BOTTOM 3) H2.5 CLIP EVERY BEARING STUD TOP AND BOTTOM 4) 3" SEWER LINE REQUIRES 1/4" /FT SLOPE 5) SEWER LINE MUST BE CONTINOUSLY SUPPORTED-BRIDGING NOT ALLOWED 6) FIREBLOCK FURRED OUT WALL 7) STRAP CORNERS WITH NON OVERLAPING TOP PLATES 8) STOPPED INSPECTION, NOT READY |