Permit: T02CM03191

Parcel: 129101240

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/20/2004 MECHANICAL - FINAL Approved IVRS - Inspection :*
10/19/2004 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*/EAST APT CONDENSATE TERMINATION INTO BATH RM. LAV. CLEAR PLASTIC TUBING INTO TRAP. 1)ELIMINATE TUBING FLOTENING OUT. NEED TUBING TO RETAIN FULL ROUND CIRCUMFRENCE 2)PROVIDE CLEARANCE, FURN. VENT TO REFRIG. LINE INSULATION ARMSFLEX IN CONTACT W/VENT PIPE 3)WEST APT. STABILIZE SINGLE WALL VENT CONNECTOR-NEEDS TO BE KEPT FROM MOVING CLOSE TO DOOR CASING-(COMBUSTIBLE) AND REFRIG. LINES. CORRECT/RECALL