Inspection History Details
Inspection Status: Denied
Inspection History: FRAMING
Permit Number - T02CM03164
Inspection Description - FRAMING
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/04/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) GABLE END DIAGONAL BRACING MUST ATTACH TO THE TOP PLATE AND HAVE CONTINOUS BRACING AT MIDSPAN PER DT1/10 2) ALL A/C AND HEATER REGISTERS NEED TO BE BLOCKED ON 3 SIDES 3) INSTALL BANG PLATES ON TOP PLATE OF MAIN BATH LAV WATER PIPING 4) A/C CONDENSATE PIPING NOT COMPLETED | |
09/04/2002 | FRAMING | Approved | IVRS - Inspection 0000* |