Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/14/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/13/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP NON-CABIN TIED TOP PLATES-TOP COUNTERS 2) CLIP STUDS AND STRAP TRUSS DOWN AT EAST GARAGE WALL 3) SD-1-16B-USE DETAIL FOR FRONT COLUMN 4) STRAP FRONT COLUMN TOP PLATES TO ADJOINING HEADER-EAST SIDE AND NORTH SIDE TOP PLATE DOWN TO KINGS 5) CORRECT A-35'S INSTALL ON PATIO LEDGER |