Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM03142
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/14/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
08/13/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NO WATER IN SEWER AND VENT PIPING 2) MASTER BATHROOM, PEX WATER PIPING MUST BE AT LEAST 12" AWAY FROM LIGHT FIXTURE CAN 3) REMOVE AND REPLACE DIAGONAL BRACE ON GABLE END TRUSS ON NORTH SIDE OF MASTER BEDROOM. NOT PROPERLY FITTED 4) BRACE GAS PIPING AT SWING JOINT IN KITCHEN PIPING GOING TO DRYER 5) MESH AND FOAM NOT COMPLETED ON WEST GABLE END |