Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T02CM03130
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2002 | ROOF NAILING | Approved | IVRS - Inspection 0000* | |
08/26/2002 | ROOF NAILING | Denied | IVRS - Inspection 0999*/ 1) ROOF NOT PROPERLY NAILED. NAIL ALL ENDS AND SUPPORTED EDGES AT 6" ON CENTER AND FIELD AT 12" ON CENTER ALSO DECK 2) ROMEX INTO JUNCTION BOX REQUIRES ROMEX CLAMP 3) STAIR TREADS ALL MUST BE SAME WIDTH AND AT LEAST 10" IN WIDTH 4) STAIR RISER CANNOT HAVE OPENINGS LARGER THAN 4" |