Permit: T02CM03089

Parcel: 141300960

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM03089

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/30/2002 FRAMING Approved IVRS - Inspection 0000*
08/29/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*
08/28/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) SECURE A/C BOX IN KITCHEN 2) PEX LINE MUST BE MINIMUM 12" FROM CAN LIGHTS 3) VENT FAN DUCT IN 2ND FLOOR BATH MUST EXTEND TO OPENING AND MUST BE SECURED 4) FLAT VENT AT 2ND FLOOR WATER CLOSET HAS NEGATIVE GRADE