Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/12/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/09/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*1) TEST REQ'D ON DWV SYSTEM. 2) SAN-TEE NOT PERMITTED IN HORIZONTAL DRAIN 3) TRAP ARM TOO LONG AT HALL BATH 4) ADD GFCI OUTLET AT MASTER BATH 5)FRAMING OK BUT WITHELD PENDING ELECT, PLB 6)PARTIAL PENDING COMPLETION OF LATH |
| 06/06/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 06/02/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PLEASE RE-CALL 00035 WHEN STUCCO MESH IS ON AND ALL INTERMEDIATE TRADES ARE COMPLETE |
| 05/30/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |