Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/14/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/10/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 01/05/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) A-35 MISSING AT GARAGE LEDGER OVER GLU LAMS, POSITIVE CONNECTION REQUIRED FROM CRIPPLE STUDS TO GLU LAMS 2) POST CAP REQUIRES GLU LAM TO POSTS 3) FIRE BLOCK MISSING AT FIREPLACE AND LAUNDRY VENT AND COL. AT MASTER BEDROOM ENTRANCE 4) STABLIZE-STUD AT FUR PLATE FORM 5) WATER TEST REQUIRED ON PLUMBING TOP-OUT 6) ISOLATE GROUNDS AT ELECTRIC SUB PANEL IN GARAGE 7) H2.5 MISSING AT LEDGERS. THRU-OUT VARIOUS PLACES 8) H2.5 MISSING STUDS TO DOUBLE PLATE AT IN. GARAGAE BEARING 9) STOPPED INSPECTION ON SITE AT REINSPECTION |