Permit: T02CM03066

Parcel: 13217141A


Addresses:

1101 E PALMDALE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/03/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) PLUMBING FINAL OK IT COULD HAVE BEEN BETTER IF YOU HAD CAPPED OFF THE DELETED EWC IN THE WALL AS REQUESTED. 2.) OK FOR C OF O. PENDING ANY OTHER INSPECTIONS.
08/28/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) DRINKING FOUNTAIN NOT HOOKED UP 2.) PROVIDE INSPECTION HISTORY FOR YARDWATER PIPING 3.) HC WATER CLOSET REQUIRE 18" FROM SIDE WALL TO CENTER. 4.) WATER CLOSET REQUIRES 15" FROM SIDEWALL OR OBSTRUCTION TO CENTERLINE. 5.) HC URINAL TO BE 17" MAX AFF. 6.) HC URINAL FLUSH VALVE TO BE 44" AFF MAX