Permit: T02CM03025


Addresses:

2944 N CARDELL CI

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/13/2002 FRAMING Approved IVRS - Inspection 0000*
10/23/2002 FRAMING Denied IVRS - Inspection 0935*/ 1) STAIRS DO NOT COMPLY WITH IRC SECTION 314.2, EXCEED SHORTEST RISER 7 1/8" BY MORE THAN 3/8" - 7 3/4 + 2) YOU MUST PAY A REINSPECTION FEE PRIOR TO NEXT INSPECTION
10/22/2002 FRAMING Denied IVRS - Inspection 0935*/ 1) STAIR RISERS EXCEED 3/8 GREATER THAN SMALLEST RISER BY 1", 6 7/8 TO 7 7/8 PER IRC 314.2 2) DEFUSER BOOT NOT BLOCKED 3 SIDES 3) BEARING STUDS DAMAGED AT RANGE HOOD NOTCHED GREATER THAN 1/4 DEPTH
10/21/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ITEMS 3,5, AND 7 FROM 10/18/02 INSPECTION NOT FIXED 2) SMOKE DETECTOR WITHIN 36" OF AIR REGISTER 3) BLOCK DEFUSER 3 SIDES 4) BEARING STUD DAMAGED AT RANGE HOOD
10/18/2002 FRAMING Denied IVRS - Inspection 0950*/ 1) KITCHEN SHEARWALL NOT NAILED ONE STUD 2) KITCHEN HORIZONTAL VENT NOT ALLOWED BELOW 42" 3) TRUSS HANGERS MISSING NAILS 4) ANCHOR BOLTS LOOSE MISSING THROUGHOUT 5) STAIR RISE EXCEEDS 3/8" BETWEEN STEPS 6) 2ND FLOOR GLUE LAM NOT BEARING ON TRIMMERS 7) BLOCK DEFUSER BOOTS 3 SIDES 8) JOIST HANGER MISSING 9) WALLS NOT ANCHORED 10) HEADERS MUST BEAR ON TRIMMERS 11) STOPPED INSPECTIONS