Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T02CM02995
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/29/2002 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*CORRECTIONS MADE OK 2.) OK TO COVER ALL AREAS. 2.) OK TO COVER ALL AREAS. 3.) PLEASE CHANGE SCREWS IN UPSTAIRS CLOSET FLANGES TO BRASS PER T VALENCIA | |
08/28/2002 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) REPAIR AT UPSTAIRS TUB LEAKING REPAIR & RETEST. 2.) ABS DWV THRU ROOF OK PEX WATER OK CLOSET FLANGES OK 3.) OK TO COVER WALLS EXCEPT FOR LEAK AT REPAIR. | |
08/26/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. | |
08/22/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) NO WATER TEST ON WAST & VENT SYSTEM 2.) CAN NOT HAVE A FLAT FACED BUSHING ON HORIZONTAL DRAINAGE 2ND FLOOR. MUST USE BELL REDUCER.3.) WASHING MACHINE ROUGH IN NOT TO PLAN. 4.) CLOSET RING ON 2ND FLOOR REQUIRES BRASS SCREWS. 5.) 3" C.O. 1ST FL WATER CLOSET WILL BE TANK. MUST HAVE 18" MIN OF CLEARANCE. | |
08/20/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) ABS TO BE SUPPORTED AND STRAPPEDE EVERY FOUR FEET MAXIMUM HORIZONTAL. 2.) REQ'D 2 PIPE DIAMETERS MINIMUM BETWEEN WE' OF TRAP AND POINT OF VENT. 3.) CLEANOUTS REQUIRED ON HORIZONTAL BRANCH PIPING OVER FIRE FEET FROM MAIN. 4.) WATER TEST ABS THRU ROOF. | |
08/19/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. |