Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/26/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 06/27/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ROMEX WIRE CANNOT BE EXPOSED BELOW 8'-MUST BE IN METAL CONDUIT MASTER BEDROOM 2) LIGHT FIXTURE IN CLOSET CANNOT BE WITHIN 12" HORIZONTALLY OF SHELF 3) KITCHEN COUNTERS WIDER THAN 12" MUST HAVE A GFCI OUTLET 4) ALL OUTLETS ON KITCHEN COUNTERS MUST BE GFCI PROTECTED 5) KITCHEN PENSULA REQUIRES A GFCI OUTLET. NO EXTENSION COLD. 6) CORRIGATED WATER HEATER VENT CONNECTION NOT ALLOWED 7) 1" CLEARANCE TO COMBUSTIBLES REQUIRED FOR WATER HEATER CLASS "B" VENT 8) CORRIGATED WATER HEATER VENT CONNECTION NOT ALLOWED 8) ALL OUTSIDE ELECTRIC OUTLETS MUST BE GFCI PROTECTED 9) ELECTRIC SUB PANEL MUST HAVE AN ISOLATED NEUTRAL BAR WITH A BONDED GROUND BAR 1) LABEL ALL CIRCUITS IN SUB PANEL 11) PAINT ABS PLASTIC ON ROOF |