Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM02958

Parcel: 123023360


Addresses:

2725 E WAVERLY ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/26/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
06/27/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ROMEX WIRE CANNOT BE EXPOSED BELOW 8'-MUST BE IN METAL CONDUIT MASTER BEDROOM 2) LIGHT FIXTURE IN CLOSET CANNOT BE WITHIN 12" HORIZONTALLY OF SHELF 3) KITCHEN COUNTERS WIDER THAN 12" MUST HAVE A GFCI OUTLET 4) ALL OUTLETS ON KITCHEN COUNTERS MUST BE GFCI PROTECTED 5) KITCHEN PENSULA REQUIRES A GFCI OUTLET. NO EXTENSION COLD. 6) CORRIGATED WATER HEATER VENT CONNECTION NOT ALLOWED 7) 1" CLEARANCE TO COMBUSTIBLES REQUIRED FOR WATER HEATER CLASS "B" VENT 8) CORRIGATED WATER HEATER VENT CONNECTION NOT ALLOWED 8) ALL OUTSIDE ELECTRIC OUTLETS MUST BE GFCI PROTECTED 9) ELECTRIC SUB PANEL MUST HAVE AN ISOLATED NEUTRAL BAR WITH A BONDED GROUND BAR 1) LABEL ALL CIRCUITS IN SUB PANEL 11) PAINT ABS PLASTIC ON ROOF