Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T02CM02946
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/01/2002 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) OK FOR DRYWALL. | |
06/28/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) CAN NOT HAVE A HORIZONTAL VENT BELOW THE FLOOD RIM LEVEL OF FIXTURE FOR SHAMPOO SINKS. ALL HORIZONTAL VENTS MUST BE 6" ABOVE FLOOD RIM LEVEL. | |
06/26/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* |