Permit: T02CM02904

Parcel: 118040120

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/20/2007 FRAMING Approved IVRS - Inspection :*
04/13/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REVISE PLAN FOR M. CLOSET ALTERATION AND MECH. UNIT
2. PROVIDE AIR EXCHANGES IN BEDROOMS
3. TEST DWV SYSTEM
4. REPLACE BLOWN FIREBLOCKS
5. CUP STUDS TO TOP PLATE @ INTERIOR BEARING WALLS
6. LAG BOLTS FOR GARAGE LEDGER MUST HIT STUDS.
7. DRYER VENT BACKWARDS
8. EXTEND COMBUSTION AIR VENTS
9. EXTEND EXHAUST FAN DUCT
10. SCREEN T-TOPS
11. 1" CLEARANCE TO COMB. AROUND WATER HEATER B-VENT
12. EXPOSE WATER & SEWER
03/20/2003 FRAMING Partial Approval IVRS - Inspection 0000*