Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/30/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/28/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF WALL SURFACE, GARAGE 2 PLACES AND LAUNDRY ONE PLACE 2) STAIRS STRINGERS MISSING HANGERS AT HEADER NOT PROPERLY SUPPORTED 3) TRUSS JOIST CUT ABOVE LAUNDRY 4) STAIRS NOT FIRE BLOCKED 5) STAIRS DO NOT COMPLY WITH IRC SECTION 314, RISERS EXCEED 7 3/4" 6) FIREBLOCK DROP CEILING 7) HOLDOWNS NOT INSTALLED 8) OUTLET BOXES NOT INSTALLED 8) YOU MUST PAY REINSPECTION FEE PRIOR TO NEXT INSPECTION |
| 10/23/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0935*/ 1) GARAGE CEILING INSULATED WITHOUT APPROVAL-REMOVE DRYWALL STOCK FROM WALLS 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD/PLATE SURFACES 3) TJI TOP FLANGE CUT AT TUB PROVIDE BOTH ENGINEERS APPROVED REPAIR 4) TUB LEAKING 5) STAIRS DO NOT COMPLY WITH IRC SECTION 314.2-EXCEED 7 3/4" RISE AND 3/8" DIFFERENCE 6) STOPPED INSPECTION 7) YOU MUST PAY A REINSPECTION FEE PRIOR TO NEXT INSPECTION 8) SUPERINTENDENT MUST INSURE HOUSE MEETS PLAN AND ALL CODE REQUIREMENTS PRIOR TO NEXT INSPECTION |
| 10/21/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) TUB LEAK 2) MECHANICAL NOT READY 3) PROVIDE BLOCKING FOR SHEAR WALL ONE IN GARAGE AT DROP CEILING 4) HOLDOWNS NOT INSTALLED 5) STOPPED INSPECTION, NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE FOR EACH TRADE FAILING |
| 10/18/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) HOUSE NOT COMPLETE ENOUGH TO INSPECT |