Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/14/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 10/10/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL CS STRAPS PER SIMPSON 2) NAIL SHEAR PANELS AT 8' BEAMS AND PER SCHEDULE 3) HOLDOWNS NOT NAILED INTO DOUBLE FULL LENGTH STUDS 4) SEVERAL H2.5 CLIPS NOT INSTALLED OR NAILED 5) DOUBLE PLATES NOT CABIN TIED 6) STAIRS EXCEED 3/8" DIFFERENCE IN RISERS |
| 10/07/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE 1" CLEARANCE AT ENT POST FROM CONCRETE 2) BALCONY NOT NAILED OFF 3) SCUPPERS NOT CUT OUT |