Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM02874

Parcel: 110101700

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM02874

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/27/2002 FRAMING Approved IVRS - Inspection 0000*
09/24/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) NO PLANS VISIBLE ON JOB SITE ?
09/19/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) MISSING SW2 SHEARWALL AT FAMILY ROOM 2) NAIL FIREPLACE STRAPS TO TAKE WT OF FLUE 2) STUFF INSULATION IN GAS LINE HOLE AT FIREPLACE 4) FINISH MECH IN LAUNDRY 5) RETRUN PLENIUM IN GARAGE, FURN, PLATFORM 6) SECURE B/PLATE BATH, BEHIND TOILET EAST 7) BANG PLATE TUB OVERFLOW-EAST 8) ADD NAILS TO 2 X 8 LEDGER AND HANGERS BEDROOM EAST 9) LEAVE FIREPLACE BOOKLET 10) LEAVE TRUSS CALCS 11) STRAP RADIUS WALL TO TRUSS 12) IS ROOF COVERING METAL? 13) NEED TO CHECK TRUSS BEARING CEILING OF STUDY 14) POST TO BEAM CONNECTION ?