Permit: T02CM02873

Parcel: 111070120


Addresses:

2448 N SPARKMAN BL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/04/2002 FRAMING Approved IVRS - Inspection 0000*
08/30/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*NO ACCESS.
08/16/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) CANNOT APPROVE UNTIL ALL PLUMBING, ELECTRICAL AND MECHANICAL ARE APPROVED 2) PROVIDE CITY APPROVED PLUMBING, ELECTRIC AND MECHANICAL PLAN
08/12/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) SAME AS INSPECTION ON 8/9/02
08/09/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) SW BEDROOM HAS REPLACE WINDOW. INADEQUATE EGRESS. MUST HAVE A MINIMUM OF 5.7 SQUARE FEET OPENING EGRESS 2) DUCT RESTRICTED AT BOOTS TOO TIGHT OF ANGLE 3) R-6 INSULATE DUCT WORK CANNOT APPROVE FRAME UNTIL ALL TRADES COMPLETE EXTERIOR CLIP OK 4) OK TO DRY IN